Magnetic measurement system B/H Hysteresisgraph
MATS-2010SA Hysteresis graph is fully automatic, computer controlled equipment to measure on basic magnetization curve and magnetic hysteresis loop under dynamic state of soft magnetic material at continuous frequency of 1 kHz to 300 kHz, automatic measurement of magnetic hysteresis loop of the soft magnetic materials such as silicon steel, precision alloy, non-crystal and ferrite, accurate measurement on the dynamic magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, loss iron Pc, remanence Br and coercivity Hc.Windows measurement software applied simply. It conforms to China National Standards GB 5026-85, GB 3658-90, GB/T 9632.1-2002, GB/T 19346-2003, industry standard SJ/T 10281-91 and international standard IEC 60367-1, IEC 60404-6.
General Features
·Testing sample varieties: soft magnetic ferrite, permalloy, amorphous and nano crystal.
Test sample shapes: annular, E and U shapes.
·Test samples with closed magnetic circuit can be directly winded and measured on samples. Magnetizing coil (N1) and measuring coil (N2) form a no-load transformer.
·Non-inductive resistance connected on magnetizing coil loop to determine magnetizing current and magnetic field intensity through the measurement of pressure drop on non inductive resistance, magnetic field peak value can be locked through digital feedback, magnetic field lock precision 0.5%.
·Magnetic induction obtained through digital integration of coil measuring voltage, magnetic induction peak value locked through digital feedback, magnetic induction lock precision 0.5%.
·Power source and sampling amplifier integrated into a casing with simple interface: one RS232 interface connected to the computer, two way voltage alarm connected to high speed A/D card.
·Different power sources can be selected according to different test requirements: 1 kHz ~ 300 kHz or 500 kHz, 5 kHz or 10 kHz ~ 100 kHz or other frequency ranges customized.
·Measuring dynamic hysteresis loop through volammetry and digital integration can accurately measure dynamic magnetic characteristic parameters such as μa, δ, Pc, Br and Hc, and calculate μ', μ'', μL, μR, Q and AL, etc.
·Automatic and continuous measurement up to 255 testing points.
·Powerful function of the software.
System Specifications
Adopt volammetry to measure loss Ps and amplitude permeability μa and loss angle δ, when test frequency is 50 kHz, conduct test on ferrite circular ring sample with standard size (d1 = 40 mm, d2 = 32 mm, h = 6 ~ 10 mm), technical indices as follows:
Parameters measured | Bm (%) | Br (%) | Hc (%) | μa (%) | Ps (%) | δ (%) |
Uncertainty (k = 2) | 1 | 1.5 | 2 | 3 | 5 | 5 |
Repeatability (constant temperature) | ± 0.5 | ± 1 | ± 1 | ± 2 | ± 3 | ± 2 |
Instrument Specifications
TPS-200SA/300k Soft Magnet AC Test Power Supply | TPS-200SA/500k Soft Magnet AC Test Power Supply | |
Output Power: 200 VA sine wave Frequency Range: 1 kHz ~ 300 kHz Frequency Fineness: < 0.1% * Current Value Frequency Error: < 0.05% Output Voltage: 0 ~ 50 V (Peak Value) Voltage Fineness: Program Control 1 mV, panel < 10 mV Voltage Distortion Factor: Superior to 1% Voltage Stability: Superior to 0.1% Sampling Current: 0 ~ 5 A (Peak Value) Sample Voltage: 0 ~ 10 V (Peak Value) | Output Power: 200 VA sine wave (below 300 kHz) Frequency Range: 1 kHz ~ 500 kHz Frequency Fineness: < 0.1% * Current Value Frequency Error: < 0.05% Output Voltage: 0 ~ 50 V (Peak Value) Voltage Fineness: Program Control 1 mV, panel < 10 mV Voltage Distortion Factor: Superior to 1% Voltage Stability: Superior to 0.1% Sampling Current: 0 ~ 5 A (Peak Value) Sample Voltage: 0 ~ 10 V (Peak Value) | |
TPS-500A Broadband Programmable Power supply | PC6684 A/D Card | |
Output Power: 500 VA sine wave Frequency Range: 10 kHz ~ 100 kHz Frequency Fineness: < 0.1% * Current Value Frequency Error: < 0.05% Output Voltage: 0 ~ 50 V~ 100 V~ 150 V~ 300 V Voltage Fineness: Program Control 1 mV, panel < 10 mV Voltage Distortion Factor: Superior to 1% Voltage Stability: Superior to 0.1% Sampling Current: 0 ~ 10 A (Peak Value) Sample Voltage: 0 ~ 200 V (Peak Value) | Sampling Rate: 40 MHz * 2 Channels Resolution and Linearity: 12 Bits ± 1/2 LSB Voltage Range: ± 1 V Sampling Clock: 25 ns ~ 800 ns Hardware Clock Internal Storage Capacity: 512 k Bytes * 2 Bus Structure: PCI busbar | |
PC5012 A/D Card | ||
Sampling Rate: 50 MHz * 2 Channels Resolution and Linearity: 12 Bits ± 1/2 LSB Voltage Range: ± 0.1 V ~ ± 20 V Sampling Clock: 20 ns ~ 5 ms Hardware Clock Internal Storage Capacity: 4 M Bytes * 2 Bus Structure: PCI busbar |
Magnetic measurement system B/H Hysteresisgraph